Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 12 de 12
Filter
1.
Acta ortop. bras ; 32(1): e272375, 2024. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1550003

ABSTRACT

ABSTRACT Objective: To report on the experience and impressions of the Brazilian orthopedic trauma surgeons attending the Leadership Development Program (LDP) hosted by the Sociedade Brasileira do Trauma Ortopédico (SBTO) in Sao Paulo, Brazil on November 4, 2022. Methods: Forty-eight orthopedic trauma surgeons from five different regions throughout Brazil were provided a link to complete The Big Five Test, a validated online personality assessment. The questionnaire was available in Portuguese and was intended to provide a background on individual personality traits and their influence on interpersonal interactions. The LDP integrated content from literature reviews specific to Latin America, established leadership programs from leading business schools, and various subject matter experts. Prior to the start of the LDP, participants received a pre-course survey evaluating demographic information, a needs assessment, and the prioritization of leadership topics utilizing a 5-point Likert-scale. Attendees participated in the one-day, interactive LDP focusing on the fundamental principles of leadership development, communication, personal development, emotional intelligence and negotiation. Following the LDP, a post-course evaluation was administered to determine the participants' overall experience, and suggestions for LDP improvement. Results: Forty-one of the forty-eight course participants completed the pre-course evaluation, whereas forty-six of the forty-eight participants completed the post-course evaluations. Overwhelmingly, the lack of opportunity was most prevalently reported as the main obstacle to attending a leadership course, as cited by 56% of respondents. Conclusion: Expanding the accessibility, diversity, and customizability of leadership programs can facilitate the development of personal tools needed to move healthcare forward. Critical topics include emotional intelligence and other differentiating leadership qualities that distinguish true transformational and servant leaders. Advancing leadership skills can stimulate networking, expose learners to experiential learning styles, inspire others to create positive change, and engender creative solutions for systematic improvements and health outcomes. Level of Evidence III; Individual Case-Control Studies.


RESUMO Objetivo: Relatar a experiência e as impressões de cirurgiões de trauma ortopédico brasileiros participantes do Programa de Desenvolvimento de Liderança (PDL), organizado pela Sociedade Brasileira do Trauma Ortopédico (SBTO), em São Paulo, Brasil, em 4 de novembro de 2022. Métodos: Quarenta e oito cirurgiões de trauma ortopédico de cinco regiões diferentes do Brasil receberam um link para preencher o The Big Five Test, uma avaliação de personalidade on-line validada. O questionário estava disponível em português e pretendia fornecer informações básicas sobre traços de personalidade individuais e sua influência nas interações interpessoais. O PDL integrou conteúdo de análises de literatura específicas da América Latina, e programas de liderança estabelecidos pelas principais escolas de negócios e por vários especialistas no assunto. Antes do início do PDL, os participantes receberam uma pesquisa pré-curso solicitando informações demográficas, uma avaliação de necessidades e a priorização de tópicos de liderança utilizando uma escala Likert de 5 pontos. Os participantes participaram do PDL interativo de um dia com foco nos princípios fundamentais de desenvolvimento de liderança, comunicação, desenvolvimento pessoal, inteligência emocional e negociação. Após o PDL, foi realizada uma avaliação pós-curso para determinar a experiência geral dos participantes e sugestões para melhoria do PDL. Resultados: Quarenta e um dos quarenta e oito participantes do curso concluíram a avaliação pré-curso, enquanto quarenta e seis dos quarenta e oito participantes concluíram a avaliação pós-curso. A falta de oportunidade foi relatada com maior prevalência como o principal obstáculo para frequentar um curso de liderança, conforme citado por 56% dos entrevistados. Conclusão: Expandir a acessibilidade, a diversidade e a personalização dos programas de liderança podem facilitar o desenvolvimento de ferramentas pessoais necessárias para fazer avançar os cuidados de saúde. Os tópicos críticos incluem inteligência emocional e outras qualidades de liderança diferenciadas, que distinguem verdadeiros líderes transformacionais e servidores O avanço das competências de liderança pode estimular o networking, expor os alunos a estilos de aprendizagem experiencial, inspirar outros a criar mudanças positivas e gerar soluções criativas para melhorias sistemáticas dos resultados na saúde. Nível de Evidência III; Estudos de caso-controle individuais.

2.
Acta ortop. bras ; 30(6): e255963, 2022. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1419957

ABSTRACT

ABSTRACT Objective: To evaluate the age and anthropometry profile of patients with a diagnosis of fracture of the proximal femur in older adults admitted to a philanthropic hospital in São Paulo. Methods: Retrospective observational cross-sectional study. All patients older than 59 years with femoral fractures diagnosed and hospitalized between January, 2019 and April, 2020 were included. The analysis of the 85 medical records resulted in the data collected in the present study. Anthropometry, age, sex, ethnicity, presence of comorbidities and mechanism of trauma of these patients were considered in this study. Most traumas, as expect, presented low energy mechanisms. Results: Prevalence of 3:1 in females, aged between 60-104 and mean of 78.5 years, with an increased risk in patients over 80 years. The body mass index (BMI) between 16.53 and 39.80 with an average of 24.16 kg/m2. Being 89.4% cases of fall from own height. Conclusion: Proximal femur fractures in older adults occur more often in women, with a mean age of 78.5 years, normal BMI range, whose main trauma mechanism is fall to ground level. The most prevalent injury is transtrochanteric fracture, with a mean of 70.5% and the most performed treatment is internal fixation with cephalomedullary nail, with a mean of 66.1%. Level of Evidence VI, Descriptive Epidemiological Study.


RESUMO Objetivo: Avaliar o perfil de idade e antropometria dos pacientes com diagnóstico de fratura do fêmur proximal em idosos admitidos em um hospital filantrópico de São Paulo. Métodos: Estudo retrospectivo, observacional, transversal. Foram incluídos todos os pacientes com fratura do fêmur proximal e idade superior a 59 anos, internados em um hospital filantrópico de São Paulo entre janeiro de 2019 e abril de 2020. A análise dos 85 prontuários levantados resultou na coleta de dados antropométricos, idade, sexo e etnia, doenças associadas e uso de medicações, além de dados relacionados ao mecanismo de trauma. Como esperado, a maioria dos traumas apresentou mecanismo de baixa energia. Resultados: Houve predominância de 3:1 do sexo feminino, com idade entre 60 e 104 e média de 78,5 anos, havendo um risco maior para pacientes acima dos 80 anos. O índice de massa corpórea (IMC) foi de 16,53 a 39,80, com média de 24,16 kg/m2. Quanto ao mecanismo do trauma, 89,4% dos casos foram de queda da própria altura. Conclusão: Fraturas do fêmur proximal em idosos ocorrem mais em mulheres, com idade média de 78,5 anos, IMC na faixa normal e queda ao nível do solo como principal mecanismo de trauma. A lesão mais prevalente foi a fratura transtrocanteriana, com média de 70,5%, e o tratamento mais realizado foi a fixação interna com haste cefalomedular (66,1%). Nível de Evidência VI, Estudo Epidemiológico Descritivo.

3.
Acta ortop. bras ; 25(1): 48-51, Jan.-Feb. 2017. tab, graf
Article in English | LILACS | ID: biblio-837740

ABSTRACT

ABSTRACT Objective: To evaluate the frequency of deltoid ligament injury in bimalleolar supination-external rotation type fractures and whether there is a correlation between the size of the fractured medial malleolus and deltoid ligament injury . Methods: Twenty six consecutive patients underwent magnetic resonance exams after clinical and radiographic diagnosis of bimalleolar supination-external rotation type ankle fractures . Results: Thirteen patients (50%) presented deltoid ligament injury associated to bimalleolar ankle fracture. Partial injury was present in seven (26.9%) patients and total injury in six (23.1%). Regarding medial fragment size, the average was 2.88 cm in the absence of deltoid ligament injury. Partial injuries presented 1.93 cm and total 2.1 cm on average . Conclusion: Deltoid ligament injury was present in 50% of bimalleolar ankle fractures. Smaller medial malleolus fragments, especially concerning the anterior colliculus, presented greater association with partial deltoid ligament injuries. Level of Evidence IV, Cross Sectional Study.


RESUMO Objetivo: Avaliar a frequência da lesão do ligamento deltóide nas fraturas bimaleolares do tornozelo tipo supinação-rotação externa e se existe correlação entre o tamanho do fragmento do maléolo medial fraturado e o tipo de lesão do ligamento deltóide. Métodos: Vinte e seis pacientes consecutivos com diagnóstico clínico e radiográfico de fratura bimaleolar do tornozelo tipo supinação-rotação externa (Lauge-Hansen), foram submetidos ao exame de ressonância magnética do tornozelo para avaliar a presença de lesão ligamentar associada à fratura bimaleolar. Resultados: Treze pacientes (50%) apresentaram lesão do ligamento deltóide associada à fratura bimaleolar do tornozelo, sendo sete (26,9%) lesões parciais e seis (23,1%) totais. Com relação ao tamanho do fragmento do maléolo medial, na ausência de lesão do ligamento deltóide, o tamanho médio foi de 2,88 cm. Nas lesões parciais, a média foi de 1,93 cm e, nas lesões totais do ligamento deltóide, de 2,1 cm. Conclusões: A lesão do ligamento deltóide esteve presente em metade das fraturas bimaleolares do tornozelo do tipo supinação-rotação externa. Fragmentos menores do maléolo medial, especialmente do colículo anterior, tem maior associação com lesões parciais do ligamento deltóide. Nível de Evidência IV, Estudo Transversal.

4.
Rev. bras. ortop ; 52(1): 24-28, Jan.-Feb. 2017. tab, graf
Article in English | LILACS | ID: biblio-844098

ABSTRACT

ABSTRACT OBJECTIVE: To perform a retrospective radiographic assessment of the reduction and implant position in the femoral head in patients with pertrochanteric fractures treated with cephalomedullary nailing in the lateral position versus traction table. METHODS: Radiographs of patients with pertrochanteric fracture of the femur treated with cephalomedullary nailing in the lateral position and traction table were retrospectively evaluated. For the evaluation we used the anteroposterior radiographic view of the pelvis and the lateral view of the affected side. The cervicodiaphyseal angle, the tip-apex distance (TAD), and the spatial position of the cephalic component in the head were measured. Two patient groups were created, one group operated on the traction table and another group operated in the lateral position. RESULTS: Regarding the cervicodiaphyseal angle observed in the traction table group, the results of 11 patients (61.1%) were outside the acceptable parameters proposed in the present study. Both groups were equivalent regarding TAD and the position of the cephalic component in the head. CONCLUSION: A difference in the cervicodiaphyseal angle was observed; the group operated on the traction table had 11 patients (61.1%) whose measurements were outside the acceptable parameters.


RESUMO OBJETIVO: Fazer uma avaliação comparativa radiográfica retrospectiva da redução e posição do implante na cabeça femoral em pacientes com fraturas pertrocantéricas tratados com haste cefalomedular em decúbito lateral ou em mesa de tração. MÉTODOS: Foram avaliadas retrospectivamente radiografias de pacientes com diagnóstico de fratura pertrocantérica do fêmur tratados com haste cefalomedular em decúbito lateral ou em mesa de tração. Para avaliação radiográfica ambulatorial usamos as incidências anteroposterior da pelve e o perfil do lado afetado. Aferimos o ângulo cervicodiafisário, a tip-apex distance (TAD) e a posição espacial do elemento cefálico na cabeça. Foram criados dois grupos de pacientes, um operado na mesa de tração e outro em decúbito lateral. RESULTADOS: Com relaçao ao ângulo cervicodiafisário, observamos no grupo da mesa de tração 11 pacientes (61,1%) fora dos parâmetros aceitáveis propostos em nosso trabalho. Para a TAD e a posição do elemento cefálico na cabeça, os dois grupos se mostraram equivalentes. CONCLUSÃO: Observamos diferença com relação ao ângulo cervicodiafisário, no qual o grupo operado em mesa de tração apresentou 11 pacientes (61,1%) fora dos parâmetros aceitáveis.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Aged , Aged, 80 and over , Bone Screws , Femoral Fractures , Surgical Procedures, Operative
5.
Rev. bras. ortop ; 50(6): 625-630, Nov.-Dec. 2015. tab, graf
Article in Portuguese | LILACS | ID: lil-769978

ABSTRACT

To conduct a retrospective analysis on cases undergoing inspection of orthopedic damage, at an orthopedic emergency service in a teaching hospital, with the aim of evaluating patients with postoperative infection after conversion to internal osteosynthesis. METHODS: This was a retrospective analysis covering the period from June 2012 to June 2013, on patients who underwent inspection of orthopedic damage due to external fixation and subsequently were converted to definitive osteosynthesis using a nail or plate. RESULTS: We found an infection rate of 13.3% in our sample and, furthermore, found that there had been technical errors in setting up the fixator in 60.4% of the cases. CONCLUSION: We found an infection rate that we considered high, along with inadequacies in constructing the external fixator. We emphasize that this procedure is not risk-free and that training for physicians who perform this procedure should be mandatory.


Fazer uma análise retrospectiva de casos submetidos ao controle de danos ortopédicos em um pronto socorro de ortopedia de hospital-escola com o objetivo de avaliar os pacientes com infecção pós-operatória após serem convertidos para osteossíntese interna. MÉTODOS: Análise retrospectiva de pacientes de junho de 2012 a junho de 2013 submetidos ao controle de danos ortopédicos com fixador externo que posteriormente foram convertidos para osteossíntese definitiva, com haste ou placa. RESULTADOS: Encontramos uma taxa de infecção de 13,3% em nossa casuística e verificamos erros técnicos na elaboração do fixador em 60,4% das oportunidades. CONCLUSÃO: Foi encontrada uma taxa de infecção que consideramos alta, assim como de inadequações na confecção do fixador externo. Salientamos que esse procedimento não é isento de riscos e treinamento para médicos que o fazem deve ser obrigatório.


Subject(s)
Humans , Male , Female , External Fixators , Fracture Fixation, Internal , Surgical Wound Infection
6.
Rev. bras. ortop ; 50(4): 409-415, July-Aug. 2015. tab, ilus
Article in English | LILACS | ID: lil-761122

ABSTRACT

Fazer uma avaliação radiográfica retrospectiva da redução e posição do implante na cabeça femoral em pacientes com fraturas pertrocantéricas tratados com haste cefalomedular em decúbito lateral e fatores que possam interferir na qualidade da redução da fratura e posição do implante no uso dessa técnica. MÉTODOS: Foram avaliados retrospectivamente 19 pacientes com diagnóstico de fratura pertrocantérica do fêmur tratados com haste cefalomedular em decúbito lateral. Para avaliação radiográfica ambulatorial usamos as incidências anteroposterior da pelve e o perfil do lado afetado. Aferimos o ângulo cervicodiafisário, o TAD, a posição espacial do elemento cefáfilo em relação à cabeça e o diâmetro biespinhal. Para avaliação antropométrica usamos índice de massa corporal. Foram criados dois grupos de pacientes, um com todos os critérios normais (TAD < 25 mm, ângulo cervicodiafisário entre 130° e 135° e a posição do implante cefálico na cabeça femoral no quadrante central-central) e outro com alteração em algum dos critérios de melhor prognóstico. RESULTADOS: Houve predomínio do sexo feminino (57,9%), com idade média de 60 anos. Sete pacientes ficaram com a posição do implante cefálico na posição central-central, um apresentou ângulo cervicodiafisário > 135° e o TAD máximo foi de 32 mm. Consequentemente, 12 pacientes apresentaram algum dos critérios alterados (63,2%). Nenhuma das características avaliadas diferiu ou mostrou associação estatisticamente significativa entre pacientes com todos os critérios normais e algum critério alterado (p > 0,05). CONCLUSÃO: A técnica descrita permite uma boa redução e um bom posicionamento do implante, independentemente dos índices antropométricos e do tipo de fratura.


To perform a retrospective radiographic evaluation on the fracture reduction and implant position in the femoral head among patients with pertrochanteric fractures who had been treated using a cephalomedullary nail in lateral decubitus; and to assess factors that might interfere with the quality of the fracture reduction and with the implant position in using this technique. METHODS: Nineteen patients with a diagnosis of pertrochanteric fractures of the femur who had been treated using cephalomedullary nails in lateral decubitus were evaluated. For outpatient radiographic evaluations, we used the anteroposterior view of the pelvis and lateral view of the side affected. We measured the cervicodiaphyseal angle, tip-apex distance (TAD), spatial position of the cephalic element in relation to the head, and the bispinal diameter. To make an anthropometric assessment, we used the body mass index. Two groups of patients were created: one in which all the criteria were normal (TAD ≤25 mm, cervicodiaphyseal angle between 130° and 135° and cephalic implant position in the femoral head in the central-central quadrant); and another group presenting alterations in some of the criteria for best prognosis. RESULTS: Female patients predominated (57.9%) and the mean age was 60 years. Seven patients presented a central-central cephalic implant position. One patient present a cervicodiaphyseal angle >135° and the maximum TAD was 32 mm; consequently, 12 patients presented some altered criteria (63.2%). None of the characteristics evaluated differed between the patients with all their criteria normal and those with some altered criteria, or showed any statistically significant association among them ( p> 0.05). CONCLUSION: The technique described here enabled good reduction and good positioning of the implant, independent of the anthropometric indices and type of fracture.


Subject(s)
Humans , Male , Female , Femoral Fractures/surgery , Femoral Fractures/therapy , Hip Fractures
7.
Rev. bras. ortop ; 48(4): 357-361, ago. 2013. tab, graf
Article in English | LILACS | ID: lil-690278

ABSTRACT

OBJECTIVE: To minimize the occurrence of missed injuries, the tertiary evaluation was introduced consisting of reassessment of the patient, 24 hours after admission, with: complete history, physical examination, review of exams and diagnostic testing if necessary. METHODS: Observational study evaluating trauma patients admitted to a teaching hospital in São Paulo, according to a protocol for tertiary evaluation. RESULTS: Between February and May 2012, for 12 weeks, 182 patients were submitted to tertiary evaluation, 100 (55%) polytraumatized and 82 (45%) were victims of low-energy trauma. Neglected lesions were observed in 21 (11.5%) patients, who had 28 missed injuries. Of these 28 lesions, seven (25%) required surgical treatment. CONCLUSION: Strategies including formal tertiary evaluation, the protocol applied for assessing trauma victims, seem to be beneficial in these patients, regardless of the mechanism of trauma. The method is easily applied, effective and has low cost in identifying missed injuries in the victims of trauma. .


OBJETIVO: Com o intuito de minimizar a ocorrência de lesões despercebidas, foi introduzida a avaliação terciária, que consiste na reavaliação do paciente, 24 horas após sua internação, com: anamnese completa, exame físico detalhado, revisão dos exames subsidiários e complementação diagnóstica se houver necessidade. MÉTODOS: Estudo observacional que avaliou pacientes vítimas de trauma internados em hospital escola na cidade de São Paulo, guiado por protocolo para avaliação terciária. RESULTADOS: Entre fevereiro e maio de 2012, durante 12 semanas, foram submetidos à avaliação terciária 182 pacientes vítimas de trauma, 100 (55%) politraumatizados e 82 (45%) vítimas de trauma de baixa energia. As lesões negligenciadas foram observadas em 21 (11,5%) pacientes, que apresentavam 28 lesões despercebidas. Dessas 28 lesões, sete (25%) necessitaram de tratamento cirúrgico. CONCLUSÃO: Estratégias que incluem avaliação terciária formal, aplicada nas vítimas de trauma, sugerem ser benéficas aos pacientes, independentemente do mecanismo de trauma. É método de execução fácil, custo financeiro barato e efetivo na identificação de lesões negligenciadas nas vítimas de trauma. .


Subject(s)
Humans , Male , Female , Multiple Trauma , Severity of Illness Index
8.
Rev. bras. ortop ; 48(3): 221-227, May/June/2013. tab, graf
Article in English | LILACS | ID: lil-680877

ABSTRACT

OBJECTIVE: The purpose of this study was to compare different positions of plates in lateral malleolar Danis-Weber B fractures on synthetic bone: a lateral plate and a posterior antiglide plate. METHODS : Short oblique fractures of distal fibula at the level of the syndesmosys were simulated with a fibular osteotomy in sixteen synthetic fibula bones (Synbone®). Eight fractures were fixed with lateral plating associated with an independent lag screw, and the other eight were fixed with posterior antiglide plating with a lag screw through the plate. A strain gage was installed at the center of each plate at the osteotomy site. Supination and external rotation forces were applied to each of the two groups at the bend. RESULTS : The lateral position plate group suffered more deformity in response to supination forces compared to the group with the posterior antiglide plate, but this result was not statistically significant. In the tests with external rotation forces, the posterior antiglide plating group had significantly higher resistance (p < 0.05). CONCLUSION : When subjected to external rotation forces, osteosynthesis with posterior antiglide plate models simulating type B fractures of the lateral malleolus of the ankle is more resistant than that of the neutralization plate. .


OBJETIVO: Comparar a resistência mecânica da fixação do maléolo lateral do tornozelo com placa em posição lateral ou posterior com o maléolo em modelos de fíbula sintética, com simulação de fraturas tipo B de Danis-Weber. MÉTODO: A simulação da fratura em 16 fíbulas sintéticas (Synbone®) foi feita por corte oblíquo com serra oscilatória de 1 mm. Em oito modelos, a falha foi fixada por placa de neutralização (posição lateral); as demais por placa anticisalhante (posição posterior). Em seguida instalamos um extensômetro no centro de cada placa, visando a mensurar a deformação determinada pelas forças em supinação produzidas durante experimento na bancada nos dois grupos. Outro ensaio foi produzido com força de rotação externa sobre o implante. RESULTADOS : O grupo com osteossíntese de neutralização sofreu deformação maior aos esforços em supinação quando comparado com o grupo com placa anticisalhante, porém sem significância estatística. Nos ensaios com força em rotação externa houve significância estatística em favor da eficiência das placas posteriores (p < 0,05). CONCLUSÃO : A osteossíntese com placa anticisalhante em modelos que simulam fraturas tipo B do maléolo lateral do tornozelo é mais resistente do que a placa de neutralização quando submetidas às forças em rotação externa. .


Subject(s)
Ankle Injuries , Bone Plates , Clinical Trial , Fibula , Fracture Fixation, Internal , Tibial Fractures , Biomechanical Phenomena
9.
Acta ortop. bras ; 18(5): 255-260, 2010. ilus, tab
Article in Portuguese | LILACS | ID: lil-562081

ABSTRACT

OBJETIVO: Avaliação radiográfica, funcional e das complicações do tratamento cirúrgico das fraturas diafisárias do fêmur associadas à fratura transtrocantérica ou do colo do mesmo fêmur. MÉTODOS: De 2002 a 2007 foram tratados 17 pacientes. Eram masculinos 88 por cento e a idade média foi de 31 anos e três meses. Dez (59 por cento) apresentavam associação com fratura do colo do fêmur e sete (41 por cento) com a fratura transtrocantérica. Foram avaliados a dor residual e a amplitude de movimento articular do quadril e joelho, a consolidação radiográfica e o tipo de implante utilizado, pela avaliação atual e retrospectivamente pelo prontuário, com um seguimento médio de 48 meses. RESULTADOS: Todas as fraturas transtrocantéricas evoluíram para consolidação sem deformidade residual. Das fraturas do colo, três (30 por cento) apresentaram retardo da consolidação, e duas consolidaram em varo. Dois pacientes apresentaram retardo de consolidação da fratura diafisária. Todas as fraturas associadas trans-diáfise apresentaram resultado funcional excelente ou bom. Das associadas colo-diáfise, sete (70 por cento) apresentaram resultado funcional excelente ou bom, dois regular e um ruim. CONCLUSÃO: As fraturas associadas da diáfise do fêmur com fratura transtrocantérica apresentaram melhor resultado radiográfico e funcional com menos complicações que a associação da fratura diafisária com a fratura do colo do fêmur.


OBJECTIVE: To perform a radiographic and functional evaluation of the complications of diaphyseal fractures of the femur associated with ipsilateral fractures of the trochanter or the neck of the femur. METHODS: From 2002 to 2007, seventeen patients were treated, of which 88 percent were men, with a mean age of thirty-one years and three months. Ten (59 percent) had associated fractures of the femoral neck and seven (41 percent) had associated trochanteric fractures. The final range of motion of the hip and knee, the radiographic fracture consolidation, and the type of implant, used were evaluated, both at the time and retrospectively, based on the patients' records. The mean follow-up time was 48 months. RESULTS: All the trochanteric fractures consolidated without residual deformities. Of the femoral neck fractures, three (30 percent) presented delayed consolidation and two consolidated with in varus deformity. Two patients had delayed diaphyseal consolidation. All the ssociated diaphyseal/trochanteric fractures had good or excellent functional outcomes. Of the associated neck fractures, seven (70 percent) had excellent or good results, two had regular results, and one had a bad result. CONCLUSIONS: The association of diaphyseal with trochanteric femur fractures showed better radiographic and functional results, with less complications, than the association of diaphyseal and femoral neck fractures.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Fracture Fixation, Intramedullary , Fracture Fixation, Intramedullary/methods , Femoral Fractures/surgery , Femoral Fractures , Femoral Fractures/rehabilitation , Hip Fractures/rehabilitation , Continuity of Patient Care , Diaphyses
10.
Rev. bras. ortop ; 43(6): 248-255, jun. 2008. ilus, graf, tab
Article in Portuguese | LILACS | ID: lil-488583

ABSTRACT

OBJETIVO: Determinar a resistência mecânica à tração e à flexão de três modelos de pinos de Schanz, dois disponíveis no Brasil e o proposto neste estudo: o cônico com 4,0 a 5,0mm de diâmetro máximo, o pino com diâmetro de 5,0mm, comprimento de rosca de 40mm e alma de 3,2mm e o proposto neste trabalho, com 5,0mm de diâmetro, alma de 3,2mm e comprimento de rosca de 15mm, com o propósito de apontar o mais eficaz. MÉTODOS: Foram construídos 48 corpos de provas, distribuídos em seis grupos com oito corpos cada. A resistência à tração foi testada nos grupos 1, 2 e 3 utilizando-se uma máquina de tração de fabricação ITM®. Para verificar a resistência à flexão, nos grupos 4, 5 e 6, foram usados um perfurador de bancada, marca Cardoso® FFC-20 na instalação do pino e, em seguida, a máquina universal de ensaios ZD100PU. RESULTADOS: Nos testes de tração os pinos cônicos suportaram a tração média de 98,462kgf; os de rosca uniforme longa (40mm), 283,70kgf; e os pinos propostos com rosca uniforme de 15mm, a força média de 116,947kgf. A diferença estatística não foi significante entre os grupos. Nos testes de flexão, os pinos cônicos resistiram à força de 6,563kgf; os pinos com rosca uniforme de 40mm, à força média de 6,177kgf; e os pinos propostos, à força média de 30,275kgf, existindo diferença significativa com os grupos anteriores. CONCLUSÕES: Os três modelos de pinos de Schanz apresentaram resistência equivalente à tração e o modelo proposto - comprimento de rosca de 15mm - é significativamente mais resistente às forças de flexão.


OBJECTIVE: To determine the mechanical resistance to traction and flexion of three models of Schanz pins, two of them available in Brazil, and the one proposed in this study: a conic pin with 5.0 mm diameter, 40 mm thread length, 3.2 mm bore, and the one proposed in this paper, with 5.0 mm in diameter, 3.2 mm bore, and 15 mm thread length, in order to show which one is the most effective. METHODS: The authors built 48 test samples divided in six groups, with eight sample per group. Traction strength was tested in groups 1, 2, and 3 using a traction machine manufactured by ITM®. To check flexion strength in groups 4, 5, and 6, they used a bench perforator manufactured by Cardoso® FFC-20 in the pin installation, and then the Universal Assay Machine ZD100PU. RESULTS: In traction tests, the conic pins stood a mean traction of 98.462 kgf, those with uniform long thread (40 mm) 283.70 kgf, and the proposed pins with uniform thread of 15 mm, stood the mean strength of 116.947 kgf. The statistic difference among the groups was not significant. In the flexion test, the conic pins stood a strength of 6.563 kgf, the pins with uniform thread of 40 mm stood the mean strength of 6.177 kgf, and the proposed pins stood the mean strength of 30.275 kgf, there being a significant difference when compared to the previous groups. CONCLUSIONS: The three models of Schanz pins presented equivalent traction strength, and the proposed model - thread length of 15 mm - is significant more resistant to flexion strengths.


Subject(s)
Bone Nails , External Fixators , Materials Science
11.
Rev. bras. ortop ; 43(1/2): 31-40, jan.-fev. 2008. ilus, tab
Article in Portuguese | LILACS | ID: lil-482019

ABSTRACT

OBJETIVO: Avaliar a eficácia do fixador externo não transfixante como tratamento provisório das fraturas expostas Gustilo e Anderson graus I e II. MÉTODOS: Em estudo prospectivo, 36 fraturas expostas da diáfise da tíbia foram tratadas seqüencialmente com fixador não transfixante seguido por haste intramedular maciça bloqueada não fresada. A média de idade foi de 28 anos e 88,9 por cento dos pacientes eram do sexo masculino. O mecanismo de trauma foi: acidente motociclístico em 47,1 por cento, atropelamento em 36,1 por cento. Entre os pacientes, nove (25,0 por cento) apresentaram lesões associadas. Segundo a classificação AO, 12 pacientes (33,3 por cento) haviam sofrido fraturas do tipo A, 18 (50,0 por cento) do tipo B e seis (16,6 por cento) fraturas tipo C. Segundo a classificação de Gustilo e Anderson, 13 pacientes (36,1 por cento) eram portadores de fraturas expostas grau I e 23 (63,9 por cento), de fraturas grau II. O tempo médio de fixação externa foi de seis dias, variando de três a 22 dias. RESULTADOS: Entre os pacientes, 32 evoluíram satisfatoriamente. As complicações relacionadas ao fixador existiram em quatro pacientes: em três houve impossibilidade de conversão com o fixador instalado e em um ocorreu neurapraxia do fibular superficial. CONCLUSÃO: O fixador externo não transfixante é útil como fixação provisória das fraturas expostas da diáfise da tíbia quando se visa a conversão para osteossíntese intramedular.


OBJECTIVE: To evaluate the effectiveness of the pinless external fixator for the provisional treatment of Gustilo and Anderson grade I and II open fractures. METHODS: In a prospective study, 36 open diaphyseal fractures of the tibia were sequentially treated with a pinless fixator followed by massive, blocked, non-edged intramedullary nail. Mean age was 28 years, and 88.9 percent of the patients were male. The mechanism of trauma was: motorcycle accident in 47.1 percent, being run over by vehicle in 36.1 percent. Among the patients, 9 (25.0 percent) had associated lesions. According to the AO classification, 12 patients (33.3 percent) had suffered type A fractures, 18 patients (50.0 percent), type B fractures, and 6 patients (16.6 percent), type C fractures. According to the Gustilo and Anderson classification, 13 patients (36.1 percent) had grade I opened fractures, and 23 (63.9 percent) had grade II fractures. The mean time of external fixation was six days, ranging from 3 to 22 days. RESULTS: 32 patients had a satisfactory evolution. Fixator-related complications were seen in four patients: in three, the installed fixator could not be converted, and one had surface fibular neurapraxia. CONCLUSION: The pinless external fixation helps as provisional fixation of open diaphyseal fractures of the tibial when the intention is to later convert to intramedullary osteosynthesis.


Subject(s)
Humans , Male , Female , Adolescent , Adult , Middle Aged , Diaphyses , External Fixators , Fracture Fixation, Intramedullary , Fractures, Open , Tibial Fractures , Prospective Studies
12.
Rev. bras. ortop ; 38(3): 106-116, mar. 2003. ilus, tab
Article in Portuguese | LILACS | ID: lil-360778

ABSTRACT

Os autores testaram mecanicamente quatro montagens de fixadores externos monolaterais submetidos a forças de flexão. Em todos os corpos de provas foi deixado um intervalo de 3cm entre os segmentos para simular uma fratura instável. Os corpos de prova foram divididos em quatro grupos de acordo com o tipo e número de barras utilizadas: uma barra lisa, duas barras lisas, uma barra recartilhada e duas barras recartilhadas. Além da força de torção necessária para tornar instável o sistema de fixação, foram avaliados também os desvios axial e lateral entre os segmentos do corpo de prova, no local do corte central, com 4,5°, 9°, 13,5° e 18° de torção. Os autores obtiveram como resultados que os quatro grupos de configurações do fixador externo monolateral foram eficientes para suportar a força de torção progressivamente maior, demonstrando resistência do sistema, independentemente do tipo ou quantidade de barras; a utilização de barra lisa permitiu falha na interface presilha-barra mais precoce no experimento, acarretando desvios maiores no sistema; a utilização de barra recartilhada determinou maior contenção na interface presilha-barra, transferindo a deformação para os pinos de Schanz, com desvio total resultante menor; e que o uso de duas barras sugere incrementar a capacidade do sistema de suportar forças de torção.


Subject(s)
Biomechanical Phenomena , External Fixators
SELECTION OF CITATIONS
SEARCH DETAIL